Choose Language

NXFM100 Wiring

You are here:

Fill-Rite Hardware Power In / Power Out

Fill-Rite piggybacks power off the AC input. Your wiring configuration will depend on whether the pump runs on AC or DC power. For use with DC applications a Class 2 power supply is required for the board’s power.

DC

  • DC input requires 8-50V DC. Attached positive power to DC+ (terminal 1) and ground to DC- (terminal 2).
  • For output power, attach the load positive load wire to DC+ output (terminal 3) and ground to DC- (terminal 4).

Graphic of a power board showing the NXFM100 wiring DC input and output locations.

AC

  • AC input requires 100-240V AC. Attach Line power to AC L (terminal 5), Neutral to AC N (terminal 6), and Earth Ground to GND (terminal 7).
  • For output power, attach the load Line wire to the AC L output (terminal 8) and load Neutral to AC N (terminal 9).

Graphic of a power board showing the NXFM100 wiring AC input and output locations.